Ex and Exi basic

Course on electrical installations and intrinsically safe systems in hazardous areas.
15-19. jan. 2024
Vis klokkeslett
15. jan. 2024 - 09:00:16:00
16. jan. 2024 - 08:30:16:00
17. jan. 2024 - 08:30:16:00
18. jan. 2024 - 08:30:16:00
19. jan. 2024 - 08:30:16:00
Norsk
05-09. feb. 2024
Vis klokkeslett
05. feb. 2024 - 09:00:16:00
06. feb. 2024 - 08:30:16:00
07. feb. 2024 - 08:30:16:00
08. feb. 2024 - 08:30:16:00
09. feb. 2024 - 08:30:16:00
Norsk
18-22. mars 2024
Vis klokkeslett
18. mars 2024 - 09:00:16:00
19. mars 2024 - 08:30:16:00
20. mars 2024 - 08:30:16:00
21. mars 2024 - 08:30:16:00
22. mars 2024 - 08:30:16:00
Norsk
22-26. apr. 2024
Vis klokkeslett
22. apr. 2024 - 09:00:16:00
23. apr. 2024 - 08:30:16:00
24. apr. 2024 - 08:30:16:00
25. apr. 2024 - 08:30:16:00
26. apr. 2024 - 08:30:16:00
Norsk
10-14. juni 2024
Vis klokkeslett
10. juni 2024 - 09:00:16:00
11. juni 2024 - 08:30:16:00
12. juni 2024 - 08:30:16:00
13. juni 2024 - 08:30:16:00
14. juni 2024 - 08:30:16:00
Norsk
Vi kan også komme og holde kurs for din bedrift.

Kjøp dette og andre kurs på trainor.no.

Type
Klasserom
Live forelesning med en erfarer instruktør.
Kurslengde
5 dager
Hvor lang tid kurset vil ta. Se detaljer i kurstabellen.
Språk
NorskNorsk
EngelskEngelsk
Språket instruktøren snakker på under kurset.
Leverandør
Trainor
Hvem som har produsert og er ansvarlig for innholdet i kurset.

Målsetning

This course teaches participants to interpret zone maps and install electrical equipment in hazardous areas, and install and calculate the function and safety of intrinsically safe electrical circuits in hazardous areas.

Målgruppe

Electricians, technicians, engineers, automation technicians and others who work with measuring and control signals in Ex areas.

Kurset inneholder disse emnene

  • Zone classification
  • Explosion theory
  • Equipment categories and gas grouping
  • Ex Installation Guide as related to EN/IEC 60079-14 Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines) and IEC 61892-7 Mobile and fixed offshore units - Electrical installations - Part 7: hazardous areas
  • Protection methods
  • Marking
  • Temperature classes
  • IP classification
  • Cables
  • Glands
  • Earthing
  • Intrinsic Safety - philosophy
  • IS marking
  • Extractions from EN 60079-11 Intrinsically safe apparatus (Exi)
  • Energy limitation
  • Zener barriers
  • Calculations
  • Connections
  • Galvanic isolators
  • IS applications
  • Installation
  • Practical exercises in selection and installation of zener barriers.

Regelverk

According to guidelines from Offshore Norway (059) and the NFEA Ex-KOMP:2021 guidelines for training, the competence should be updated at least every five years.

Teknisk informasjon

Kursmanual

Ja, du vil få utdelt en fysisk kursmanual ved kursstart.

Relaterte kurs

Download Trainor App

You can complete eLearning courses from a mobile or tablet on the Trainor App. The free app cab be used without an internet connection, offering flexibility in where and when learning takes place.

Trainor App